The S9 Escape is the entry level CPAP model in the S9 Series. Packed with technology, users can take advantage of EPR settings with Easy-Breathe and Climate Control humidification. It is a sleek, all-in-one system that is ideal for any nightstand. ResMed has incorporated Easy-Breathe Technology along with expiratory pressure relief (EPR) to make breathing through a CPAP feel more “natural”.

Product Specifications

Pressure: 4 to 20 cm H2O (.2 increments)

Ramp Time: 0 to 45 min. (5-min. increments)

Starting Ramp Pressure: 4 to min pressure

Dimensions: 6 in x 5.5 in x 3.25 in

Bag Dimensions – Outside: 13.5 in x 12 in x 5.5 in

Machine Weight: 1.79lbs

Filters: Pollen or Hypoallergenic

Sound Level: 26 dBA

Operating Altitude: Sea level to 8500′ (2591 m)

SlimLine Air Tubing: Flexible plastic, 1.83m, 15mm inner diameter

Optional ClimateLine Tubing Length: 78 inches

Optional ClimateLine MAX Tubing Length: 75 inches

Housing Construction: Flame retardant thermoplastic

Device Set-Up: Push Dial

Available Languages: English (Default), French, Spanish, Portugese

Humidification: Optional Integrated Heated Humidifier or Pass-over Humidifier

DC Power: Only use DC Converter by ResMed for DC input or damage may occur.

Warranty: 2 Year Manufacturer

90W Power Supply:

  • Dimensions of Power Supply Only – Not including Cord or Plug: 5 1/2 inch (L) x 1 7/8 inch (W) x 1 1/4 inch (D)
  • Weight of Power Supply, Cord & Plug: 1.29 Pounds
  • Unit Input Range 100-240V, 50-60Hz,
  • Nominal for Aircraft Use 110V, 400Hz
  • Typical Power Consumption 70W (80VA)
  • Maximum Power Consumption 110W (120VA)

European Voltage Usage: Yes, outlet adapters required

Data Storage Capacity:

  • Display: 365 days summary data (up to 500 events per session.)
  • SD Memory Card: 365 days summary data and 30 Days and 7 nights detailed data

Aircraft Use: These S9 devices comply with US FFC Part 15, Class B requirements if no external data cables are used.

Max Exposure Heat for Machine: Machine should not be exposed to heat greater than 140 degrees Fahrenheit

Required Settings: 1 Pressure Setting is Required

Unless directed otherwise, CPAP.com will leave this machine at its default settings of:

  • EPR: Off
  • Ramp: On
  • Ramp Time: 20 Minutes